A2 brass finish shown. Click the image to enlarge.

UNARMOURED CABLES

A2 Industrial Cable Gland

Mechanical cable retention and sealing around the outer sheath of an unarmoured cable.

CABLE TYPE

Unarmoured

SEALING AREA

Outer sheath

Materials: Brass / Stainless steel. Specify the required finish and size with your enquiry.

UNDERSTAND THE PRODUCT

What does A2 do?

The A2 design secures an unarmoured cable at the equipment entry. Its seal acts on the outer sheath, helping form the cable-entry connection.
Start selection with the actual cable outside diameter and the enclosure entry thread. A cable cross-section alone is not enough to choose the gland size.

Before you specify

Confirm cable construction, diameter, thread and installation environment. For armoured cable termination, ask about the relevant armoured gland family.
Product ratings and approvals must be checked against the current Mega Tech documents for the supplied design.

READ THE DIMENSIONS

From the drawing to the right size.

The catalogue drawing links each dimension to the size table. Check the entry thread diameter and length alongside the permitted cable diameter range.
A: cable diameter · C: entry thread diameter · E: thread length · F: shoulder length · D: across flats
A2 dimensional drawing from the Mega Tech catalogue
Reference drawing from the Mega Tech catalogue.

COMPLETE CATALOGUE TABLE

Every listed size. Every dimension.

18 catalogue rows · Source page 4 · Dimensions in mm unless stated otherwise.
Scroll the table horizontally to see every column. † marks a source entry requiring confirmation.
SizeCable A minCable A maxEntry C ØThread E lengthShoulder FD flatsD cornersCatalogue code
16S3.571610202023MEG-A2 16S
16L4.58.51610202023MEG-A2 16L
20S811.52010222225MEG-A2 20S
20L11142010222225MEG-A2 20L
25S1417.520 †10253034MEG-A2 25S
25L17.520.42510263034MEG-A2 25L
32L20263210303640MEG-A2 32L
40S26304010314652MEG-A2 40S
40L30334015314652MEG-A2 40L
50S33385015335561MEG-A2 50S
50L38445015335662MEG-A2 50L
63S4450.56315357077.5MEG-A2 63S
63L50566315357077.5MEG-A2 63L
75S56.5627515358089MEG-A2 75S
75L62687515408089MEG-A2 75L
90S6875902050100112MEG-A2 90S
90L6878902050100112MEG-A2 90L
100L78881002250112125MEG-A2 100L
† A2-25S: the catalogue prints entry C = 20 mm. Retained as printed; confirm this pairing before ordering.

COMPLETE YOUR ENQUIRY

Accessories to discuss with your selection.

Lock nut

Discuss the matching thread and material needed to secure the gland to the enclosure.

Earth tag

Where required by the installation design, specify the compatible earth connection component.
Mega Tech stopping plug

Stopping plug

For separate unused enclosure entries. Match the entry thread and required material.
Accessories are specified separately unless your quotation confirms a complete kit.

COMPLETE THE INSTALLATION

Choose the matching accessories.

Explore lock nuts, earth tags, reducers, nipples and stopping plugs. Confirm the matching thread, material and installation needs.

LET’S GET THE DETAILS RIGHT

Tell us what your project needs.

Send your product code, cable details and quantities. If you are still comparing options, our team can help you clarify the selection.
Opens your email app with an enquiry checklist.