CABLE GLAND ACCESSORIES

Complete the connection. Every detail matters.

Securing, bonding, adapting and closing components for your cable-entry installation. Find the role of each accessory and build a clear specification.

SIX ACCESSORY FAMILIES

Choose by function.

Accessory reference photograph from the Mega Tech catalogue

Lock nuts

Secure the gland at the enclosure entry. Match the thread size and pitch; check the enclosure wall thickness and available engagement.
Accessory reference photograph from the Mega Tech catalogue

Earth tags

Provide a connection point for the specified earth conductor where required by the installation design. Confirm hole size, material and bonding requirements.
Accessory reference photograph from the Mega Tech catalogue

Stopping plugs

Close unused threaded cable entries. Specify head style, thread, material and sealing requirements; a stopping plug is not a cable gland.
Accessory reference photograph from the Mega Tech catalogue

Threaded nipples

Connect compatible threaded components. State the thread at both ends and the required length; an inch designation alone does not define the thread standard.
Accessory reference photograph from the Mega Tech catalogue

Slotted-head plugs

An alternative head design for unused entries. Select the thread and installation-tool access alongside the material and sealing requirements.
Accessory reference photograph from the Mega Tech catalogue

Thread reducers

Adapt an entry to a smaller compatible connection. Specify both male and female thread sizes and standards; the catalogue min/max notation is not an exact pairing.

01 / MEG-LB

Lock nuts

Secure the gland at the enclosure entry. Match the thread size and pitch; check the enclosure wall thickness and available engagement.
Catalogue size (mm)Reference code
M20 × 1.5MEG-LB 20
M25 × 1.5MEG-LB 25
M32 × 1.5MEG-LB 32
M40 × 1.5MEG-LB 40
M50 × 1.5MEG-LB 50
M63 × 1.5MEG-LB 63
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

02 / MEG-ET

Earth tags

Provide a connection point for the specified earth conductor where required by the installation design. Confirm hole size, material and bonding requirements.
Catalogue size (mm)Reference code
M20MEG-ET 20
M25MEG-ET 25
M32MEG-ET 32
M40MEG-ET 40
M50MEG-ET 50
M63MEG-ET 63
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

03 / MEG-SB

Stopping plugs

Close unused threaded cable entries. Specify head style, thread, material and sealing requirements; a stopping plug is not a cable gland.
Catalogue size (mm)Reference code
20MEG-SB 20
25MEG-SB 25
32MEG-SB 32
40MEG-SB 40
50MEG-SB 50
63MEG-SB 63
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

Hex-head stopping plugs · SP range

All 11 sizes and dimensions from catalogue page 12. Dimensions in mm; scroll horizontally to see every column.
SizeThread ØC maxF minD lengthL shoulderT flatCatalogue code
SP1616211910144MEG-SP 16
SP2020252315205MEG-SP 20
SP2525312815205MEG-SP 25
SP3232403615205MEG-SP 32
SP4040484415205MEG-SP 40
SP5050605515216MEG-SP 50
SP6363767020266MEG-SP 63
SP7575888020277MEG-SP 75
SP8080908520277MEG-SP 80
SP909011010020288MEG-SP 90
SP10010012011025338MEG-SP 100

04 / MEG-NB

Threaded nipples

Connect compatible threaded components. State the thread at both ends and the required length; an inch designation alone does not define the thread standard.
Nominal size (inches)Reference code
½″MEG-NB ½″
¾″MEG-NB ¾″
1″MEG-NB 1″
1.5″MEG-NB 1.5″
2″MEG-NB 2″
2.5″MEG-NB 2.5″
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

05 / MEG-SBS

Slotted-head plugs

An alternative head design for unused entries. Select the thread and installation-tool access alongside the material and sealing requirements.
Catalogue size (mm)Reference code
20MEG-SBS 20
25MEG-SBS 25
32MEG-SBS 32
40MEG-SBS 40
50MEG-SBS 50
63MEG-SBS 63
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

06 / MEG-RB

Thread reducers

Adapt an entry to a smaller compatible connection. Specify both male and female thread sizes and standards; the catalogue min/max notation is not an exact pairing.
Catalogue min × max (mm)Family code
20 × 63MEG-RB
25 × 63MEG-RB
32 × 63MEG-RB
40 × 63MEG-RB
50 × 63MEG-RB
63 × 75MEG-RB
Reference sizes from catalogue page 13. Confirm thread standard, finish and the final dimensions with your quotation.

A complete, clear enquiry.

Tell us the accessory family, gland model, male/female thread standard and size, material, finish, quantity and enclosure details. Accessories are separate items unless the quotation explicitly includes a kit.

LET’S GET THE DETAILS RIGHT

Tell us what your project needs.

Send your product code, cable details and quantities. If you are still comparing options, our team can help you clarify the selection.
Opens your email app with an enquiry checklist.